Introduction

The VICOT CTF series air handler offer state-of-the-art heat transfer technology, which are designed to fit almost anywhere and are ideal for supermarkets, hospitals, villas, residences, hotels and office buildings.

 

Performance

 

²        Efficiency range from 10SEER &13SEER

²        Nominal capacity from 1.5 to 5 Tons

Features

²        High quality galvanized panels ensure high corrosion resistance  

²        High static pressure design makes unit independent of duct system

²        The evaporator uses high efficient inner screwed copper tubes and

ripple style fins, which ensures state-of-the-art heat transfer technology

²        Special insulation design allows for quiet operation

²        Three speed motor offers selectable airflow volume

²        Advanced design allows different unique installations

²        Rigorous electrical protection designed for more safety protection

²        Patented diffusing equipment offers high energy efficiency.

 

Nomenclature

Technical Data

Indoor Unit Model

CTF018CN2

CTF024CN2

CTF030CN2

CTF036CN2

CTF048CN2

CTF060CN2

Outdoor Unit Model

CTF018NW2

CTF024NW2

CTF030NW2

CTF036NW2

CTF048NW2

CTF060NW2

Performance Data                                                                                                    

Nominal Cooling Capacity

BTU/H

17600

22600

28600

34500

47000

55500

SEER 

BTU/H-W

10

10

10

10

10

10

Power

/

208-230/60/1

Voltage Range

/

197-253

Electric Data                                                                     

Min. Operating Current

A

1.9

1.9

3.4

3.4

3.9

5.9

Max. Safety Current

A

10

15

Fan Motor Data                                                                                              

Operating Current

A

2.1

2.1

3.6

3.6

4.2

6.2

Power

HP

1/4

1/4

1/3

1/3

1/3

3/4

Speed

 

High, Medium, Low

Air Outlet Dimension

Length

INCH

16-5/8

16-5/8

16-5/8

16-5/8

16-5/8

19-3/4

Width

INCH

11

11

11

11

11

11

Refrigerant                                                                                                 

Type

 

R22

Connecting Pipe Size                                                                                            

Liquid Pipe

INCH

3/8

Gas Pipe

INCH

5/8

5/8

5/8

5/8

3/4

7/8

Drain Pan Dimension

INCH

3/4

3/4

3/4

3/4

3/4

3/4

Unit Size                                                                                                  

Length

INCH

23-5/8

23-5/8

23-5/8

23-5/8

23-5/8

23-5/8

Width

INCH

19-1/4

19-1/4

19-1/4

19-1/4

19-1/4

22-1/2

Height

INCH

37-1/2

37-1/2

37-1/2

37-1/2

41-1/4

47-1/8

Ship Weight

LB

108

108

115

115

142

174

 

 
FOOTNOTES:

 1. Indoor working conditioning: in cooling, temperature DB:27 (80 ), WB:1967

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters.

 

Technical Data

Indoor Unit Model

CTF018CN4

CTF024CN4

CTF030CN4

CTF036CN4

CTF048CN4

CTF060CN4

Outdoor Unit Model

CTF018NW4

CTF024NW4

CTF030NW4

CTF036NW4

CTF048NW5

CTF060NW5

Performance Data                                                                                                    

Nominal Cooling Capacity

BTU/H

17600

22600

28600

34500

47000

55500

SEER 

BTU/H-W

10

10

10

10

10

10

Power

/

220-240/50/1

Voltage Range

/

198-264

Electric Data                                                                                                    

Min. Operating Current

A

1.9

1.9

3.4

3.4

3.9

5.9

Max. Safety Current

A

10

15

Fan Motor Data                                                                                               

Operating Current

A

2.1

2.1

3.6

3.6

4.2

6.2

Power

HP

1/4

1/4

1/3

1/3

1/3

3/4

Speed

 

High, Medium, Low 

Air Outlet Dimension

Length

INCH

16-5/8

16-5/8

16-5/8

16-5/8

16-5/8

19-3/4

Width

INCH

11

11

11

11

11

11

Refrigerant                                                                                                

Type

 

R22

Connecting Pipe Size                                                                                            

Liquid Pipe

INCH

3/8

Gas Pipe

INCH

5/8

5/8

5/8

5/8

3/4

7/8

Drain Pan Dimension

INCH

3/4

3/4

3/4

3/4

3/4

3/4

Unit Size                                                                                                  

Length

INCH

23-5/8

23-5/8

23-5/8

23-5/8

23-5/8

23-5/8

Width

INCH

19-1/4

19-1/4

19-1/4

19-1/4

19-1/4

22-1/2

Height

INCH

37-1/2

37-1/2

37-1/2

37-1/2

41-1/4

47-1/8

Ship Weight

LB

108

108

115

115

142

174

 

FOOTNOTES:

 1. Indoor working conditioning: in cooling, temperature DB:27 (80 ), WB:1967

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters.


Technical Data

Indoor unit Model

CTRF 018CN2

CTRF 024CN2

CTRF 030CN2

CTRF 036CN2

CTRF 042CN2

CTRF 048CN2

CTRF 060CN2

Outdoor unit Model

CTRF018AW2

CTRF 024AW2

CTRF 030AW2

CTRF 036AW2

CTRF 042AW2

CTRF 048AW2

CTRF 060AW2

Performance Data

Nominal Cooling Capacity

BTU/H

18500

23800

29500

36000

41000

46500

56500

SEER 

BTU/H-W

13

13

13

13

13

13

13

Power

/

208-230/60/1

Voltage Range

/

197-252

Electric Data

Min. Operating Current

A

2.2

2.2

3.0

3.0

3.8

3.8

3.8

Max. Safety Current

A

10

15

Fan Motor Data

Operating Current

A

2.0

2.0

2.7

2.7

3.2

3.2

3.2

Power

HP

1/2

1/2

3/4

3/4

7/8

7/8

7/8

Speed

 

High, Medium, Low

Air Outlet Dimension

Length

INCH

19-3/4

19-3/4

19-3/4

19-3/4

19-3/4

19-3/4

19-3/4

Width

INCH

11

11

11

11

11

11

11

Refrigerant

Type

 

R22

Connecting Pipe Size

Liquid Pipe

INCH

3/8

Gas Pipe

INCH

3/4

3/4

3/4

3/4

3/4

3/4

7/8

Drain Pan Dimension

INCH

3/4

3/4

3/4

3/4

3/4

3/4

3/4

Unit Size

Length

INCH

26-1/2

26-1/2

26-1/2

26-1/2

26-1/2

26-1/2

26-1/2

Width

INCH

18-7/8

18-7/8

18-7/8

22-1/2

22-1/2

22-1/2

22-1/2

Height

INCH

46-7/8

46-7/8

46-7/8

46-7/8

46-7/8

46-7/8

46-7/8

Ship Weight

LB

132

132

132

165

165

192

192

                       

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 FOOTNOTES:

1. Indoor working conditioning: in cooling, temperature DB:27 (81 ), WB:1967

2. Fan Power is measured under high velocity running at the standard conditions.

3. The parameters are measured when the connecting pipe between outdoor unit and indoor unit is 7.5 meters

 

Our Technical Partners


Coldcare Nigeria Limited is in technical partnership with acclaimed world leaders in related engineering services. This has helped us in the areas of training as well as research and development. This way, we are able to remain relevant and up-to-date in the ever-evolving engineering world

Read More...

Our Clients...


Our success is vested in our client's success  and we do our best to keep their satisfactions as our paramount goal.

 Among our highly esteemed clients are  Airtel Nigeria, Nigerian Bottling Company Plc, Reftech A/S, Gurara Bottling Company Limited, Hassan Plastics Limited, 


Read More...

Health Safety & Environment


COLDCARE NIGERIA LIMITED places high premium on Health, Safety and Environment (HSE). Our policy makes it mandatory for everyone who works for the company, Including contractual to adhere strictly to HSE performance standards.

Read More...

OUR VISION

Our Vision is to be a household name of international standard in the provision of quality engineering products and services.

  OUR MISSION:

To keep to the ideal of high ethical standards in providing quality and efficient services to our customers at reasonable cost